Here's a comprehensive table summarizing the key aspects of Flat Roof Fall Ratio:

AspectDetails
Recommended Minimum Fall1:80 (0.72°)13
Design FallTo achieve 1:80 fall, design for 1:40 (1.44°)13
ImportancePrevents water pooling, increases longevity, reduces risk of leaks, maintains thermal efficiency4
Calculation MethodFall = Rise / Run, often expressed as 1/4 inch per foot
Building RegulationsPart H requires a minimum fall of 1:80, with design to 1:401
British StandardsBS12056, BS6229, BS8217, and BS8218 all emphasize the need for proper falls1
Internal GuttersShould be designed to the same criteria as the main roof area13
Zero FallsOnly acceptable with certified systems, but a design fall of 1:80 should still be allowed3
Implementation MethodsTapered insulation systems, structural sloping, liquid membrane solutions4
NHBC GuidanceFor tapered insulation, falls should be no less than 1:602

This table provides a comprehensive overview of the essential information regarding Flat Roof Fall Ratio. It covers the recommended minimum fall, design considerations, importance, calculation methods, regulatory requirements, and implementation techniques. This information is crucial for ensuring proper drainage, longevity, and efficiency of flat roofing systems.